VIB Protocol

QR for this page

From Fiji

Jump to: navigation, search
VIB Protocol (ImageJ)
Author Benjamin Schmid, Johannes Schindelin
Maintainer Johannes Schindelin
File [1]
Source [2]
Initial release 13 July 2008
Latest version 13 July 2008
Development status beta
Category Registration
Website Registration


Purpose

The VIB Protocol is designed for aligning 3D image stacks. The images we used are confocal images of adult fly brains, but basically the VIB protocol can be used for any 3D images.

The workflow is thereby as follows:

  • Load the input images. If they consist of several channels, the channels are splitted.
  • Label the reference channel
  • Resize images and labels
  • Calculate the centers of gravity and use them to calculate a rough alignment
  • Register each labelled region indivudually, again rigidly.
  • Interpolate the displacement field between labelled regions.

The output of the VIB Protocol is written to a user-specified folder. A description of how to use this plugin can found below, while a more detailed description about how the VIB Protocol works can be found in this presentation, which was shown at the FENS 2008 in Geneve. There exists also a movie which demonstrates nicely the alignment of two brains.

Documentation

The VIB Protocol starts with the following dialog:

VIB Protocol 1.png

A configuration file stores all the settings for running the VIB Protocol on a particular data set. It is saved in the output directory. If one wants to run the algorithm a second time, it is possible to load (and modify) the previous configuration. If you run this for the first time, just leave the text field blanc and click OK.

After that, a second dialog appears, which asks the user for all the necessary input:

VIB Protocol 2.png

The different fields have the following meaning:

Files
Use the buttons "Add to files" and "Delete from files" to add here the input images.
Working directory
All the output of the VIB Protocol goes into this folder.
Template
Choose one of the images in the "Files" list as a template (reference) brain (by selecting it in the list and clicking "Use as template"). Alternatively, you can choose an external reference by typing the path to the file you want to use.
No of channels
The number of channels contained in the input files.
No of reference channel
The number of the reference channel. The reference channel will be used for labelling.
Resampling factor
In order to speed up execution time, it is a good idea to scale the images down. Selecting here '2' for example means that a 1024x1024x256 images will be downsampled to 256x256x64.

Clicking OK will finally start the VIB Protocol. At this point, the above mentioned configuration file is created and saved, which is shown by:

VIB Protocol 3.png

Normally, the Segmentation Editor opens during the software execution and asks the user to label the brains. This step is omitted if there exists already a folder called 'labels' in the output directory and if this folder contains for each image the corresponding labels image. After that, no more user interaction is required, and the software finishes after some time. All the results can be found in the output directory. The structure of this directory is as follows:

VIB Protocol 4.png