Bug 168 - "Reduce Dimensionality..." always results in z stacks when reducing to a single dimension
"Reduce Dimensionality..." always results in z stacks when reducing to a sing...
Status: RESOLVED FIXED
Product: Fiji
Classification: Unclassified
Component: Other
unspecified
Macintosh Mac OS
: P2 enhancement
Assigned To: Johannes Schindelin
Depends on:
Blocks:
 
Reported: 2010-05-17 19:16 CDT by Jan Eglinger
Modified: 2011-10-20 02:00 CDT
0 users

See Also:

Description Jan Eglinger 2010-05-17 19:16:51 CDT
When reducing the dimensionality of an XYCZT stack (like "Mitosis (26MB, 5D stack)") to an XYZ, XYC or XYT stack by Image>Hyperstacks>"Reduce Dimensionality...", the resulting stack always gets a z-slider. This is confusing to new users, and the handy play-button in case of an XYT stack is really missing.

(When reducing by only one dimension to e.g. XYZT, everything is fine, because the resulting stack is still a hyperstack...)

Cheers,
Jan
Comment 1 Wayne Rasband 2010-05-17 20:19:01 CDT
This appears to be a bug in ImageJA. The problem goes away when you use the Help>Update ImageJ command in Fiji to upgrade to ImageJ 1.44a.

-wayne
Comment 2 Johannes Schindelin 2011-04-13 18:33:17 CDT
I just tested, and the only problem I see is when I reduce to XYZ, but because it shows a _t_ slider.
Comment 3 Jan Eglinger 2011-04-14 00:15:05 CDT
(In reply to comment #2)
The behaviour was different at the time of reporting this bug.

I'm fine with the way it currently behaves. Reducing to XYZ showing a t slider is incorrect but can be even regarded as a feature, since the play button is useful to animate in z as well, as long as there is no t dimension.

I suggest this bug can be closed.